?? FMT (FORMAT := OFF) ??
*copyc cmc$condition_limits

 CONST
   cmc$reserve_element_error = cmc$min_ecc + 900,

   cme$element_not_reservable     = cmc$reserve_element_error + 0,
    {E +P1 is not reservable. }

   cme$incorrect_element_type     = cmc$reserve_element_error + 1,
    {E Requested element type does not match element type found ..
    {in active configuration for +P1. }

   cme$privileged_job_required    = cmc$reserve_element_error + 2,
    {E Insufficient privilege to perform +P1 request. }

   cme$element_not_storage_device = cmc$reserve_element_error + 3,
    {E Element name or hardware address is not a storage device ..
    {in +P1. }

   cme$specific_pp_not_reservable = cmc$reserve_element_error + 4,
    {E A specific pp cannot be reserved at this time. }

   cme$element_already_reserved   = cmc$reserve_element_error + 6,
    {E +P1 is already reserved by: +P2.}

   cme$element_state_not_proper   = cmc$reserve_element_error + 8,
    {E +P1 is NOT in ON state.}

   cme$element_unavailable_in_170 = cmc$reserve_element_error + 10,
    {E +P1 is not available in the NOS or NOS/BE system.}

   cme$invalid_state_in_mainframe = cmc$reserve_element_error + 12,
    {E +P1 needs to be in the DOWN or OFF state in mainframe +P2.}

   cme$element_not_reserved       = cmc$reserve_element_error + 14,
    {E +P1 is not reserved to this job. }

   cme$reserve_not_permitted      = cmc$reserve_element_error + 16,
    {E Job already has +P1 reserved to it; reservation of +P2 ..
    {not permitted. }

   cme$element_downline_connected =  cmc$reserve_element_error + 18,
    {E +P1 has at least one element connected to it which is ..
    {not in the OFF state.}

   cme$cm_table_empty             =  cmc$reserve_element_error + 20,
    {E Configuration table is empty. }

   cme$active_pc_empty            =  cmc$reserve_element_error + 22,
    {E Active physical configuration table is empty. }

   cme$page_size_too_small = cmc$reserve_element_error + 23,
    {E The page size is required to be at least 4096 bytes ..
    {   in order to get contiguous memory. }

   cme$cm_element_not_found       =  cmc$reserve_element_error + 24,
    {E Element +P1 NOT found in configuration table. }

   cme$too_many_pp_program_desc   =  cmc$reserve_element_error + 26,
    {E CMP$EXECUTE_PP_PROGRAM allows no more than two program descriptions. }

   cme$reserve_request_required   =  cmc$reserve_element_error + 28,
    {E Storage device +P1 must be RESERVED or REQUESTED (dedicated or
    { maintenance) by this job for the mounting of a medium on it. }

   cme$buffer_length_too_large = cmc$reserve_element_error + 29,
    {E The requested communication buffer length exceeds the ..
    { maximum page size. }

   cme$mount_storage_medium       =  cmc$reserve_element_error + 30,
    {I Mount medium +P1 on device +P2  (mode = +P3). }

   cme$message_to_operator        =  cmc$reserve_element_error + 32,
    {I Do ASSIGN_DEVICE again with device = +P1. }

   cme$lcm_device_attached_to_job =  cmc$reserve_element_error + 34,
    {E Storage device +P1 is already attached to this job. }

   cme$lcm_device_busy            =  cmc$reserve_element_error + 36,
    {E Storage device +P1 is busy (assigned by job: +P2). }

   cme$mount_media_denied         =  cmc$reserve_element_error + 38;
    {E CMP$MOUNT_STORAGE_MEDIUM not allowed on mass storage device (+P1) ..
    {which is the object of CONCURRENT maintenance. }