~"  CREATE_MESSAGE_MODULE  TCM$5744_HELP_MODULE$US_ENGLISH
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=ACS_FULL
                    NOS/VE Tape Action Message

  Status                : 5744 Library ACS is full.
  ACS:                  : ~P1

  Action: Please remove at least 1 cartridge from the named ACS or
          the system will not be able to dismount any currently
          mounted cartridges from the drives in this ACS.
~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=AUDIT_IN_PROGRESS
                    NOS/VE Tape Action Message

  Status                : Request processing in 5744 Library is being
                          delayed by Library Audit.
~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=DRIVE_OFFLINE
                    NOS/VE Tape Action Message

  Status                : 5744 Library drive element is offline.
  NOS/VE Element:       : ~P1
  5744 Library Element  : ~P2

  Action: If you VARIED the drive to OFFLINE on the workstation then use
          LCU to change the element's state in the NOS/VE to OFF or DOWN.
          Otherwise VARY the element ONLINE at the workstation console.

~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=LSM_OFFLINE
                    NOS/VE Tape Action Message

  Status                : 5744 Library LSM element is offline.
  5744 Library Element  : ~P1

  Action: VARY the specified LSM to ONLINE at the workstation's console.
          Otherwise use LCU to change the element state in the NOS/VE
          to OFF or DOWN for all of the drives associated with this LSM.
~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=MISPLACED_CARTRIDGE
                    NOS/VE Tape Action Message

  Status                : Cartridge has been misplaced in 5744 Library.
  Volume                : ~P1

  Action: In order to locate the specified volume in the 5744 Library
          and to correct its data base the AUDIT process should be
          initiated on the workstation. Until this process completes
          the cartridge volume will remain inaccessible.
~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=MISPLACED_CARTRIDGE_USER_MSG
 Cartridge volume ~P1 has been misplaced in the 5744 library.
~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=NOT_IN_SAME_ACS
                    NOS/VE Tape Action Message

  Status                : Cartridge has been moved in 5744 Library.
  Volume                : ~P1
  ACS                   : ~P2


  The mount request is being delayed because the specified cartridge
  has been moved by the operator to another ACS.
~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=UNREADABLE_LABEL
                    NOS/VE Tape Action Message

  Status                : Cartridge has robotically unreadable label.
  Volume                : ~P1

  Action: The external label of the specified cartridge must be repaired.
          The cartridge will be ejected from the library during the next
          AUDIT operation at the workstation. Until AUDIT is performed
          the cartridge will not be accessible for usage.
~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=UNREADABLE_LABEL_USER_MSG
 Cartridge ~P1 has robotically unreadable external label.
~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=VOLUME_IN_DRIVE
                    NOS/VE Tape Action Message

  Status                : Cartridge mounted on unconfigured tape drive.
  Volume                : ~P1
  Drive:                : ~P2

  Action: The specified cartridge has been mounted on a tape drive
          which is not configured in this NOS/VE system. This causes
          a delay in processing the pending request in this system
          until the cartridge is dismounted from the drive.
~"**
~"CREATE_PARAMETER_PROMPT_MESSAGE NAME=VOLUME_IN_DRIVE_USER_MSG
 Cartridge ~P1 is mounted on an unconfigured tape drive.
~"**
~"END_MESSAGE_MODULE CREATE_MODULE=YES