A section  covering air  pollutants is being added to the  environmental
test  manual.  Below is my brief  summary of its  contents.  Please keep
this in mind as you select  components and materials for use in FIREFOX,
since it will be sold into the Industrial environment.

Craig
------------------------------------cut here---------------------------------

     SSSSeeeeccccttttiiiioooonnnn 777766668888 ---- AAAAiiiirrrr PPPPoooolllllllluuuuttttaaaannnnttttssss,,,, PPPPaaaarrrrttttiiiicccclllleeeessss,,,, aaaannnndddd MMMMeeeettttaaaallll	CCCCoooorrrrrrrroooossssiiiioooonnnn
     RRRRaaaatttteeeessss

     This is a new section. Defines quantitatively  the	 customer
     environments:  Business, Industrial, and Severe, in terms of
     metal corrosion  rates  in	 Angstroms  per	 year,	pollution
     concentrations   in   parts   per	 billion,   and	 particle
     concentrations in micrograms of  non-settleable  solids  per
     cubic  meter.  The	product	must perform reliably through the
     product's projected life (10 years	for business, 5	years for
     industrial).

     All HP products  must  perform  reliably  at  least  in  the
     Business  environment,  and no special attention needs to be



     Environmental Manual Changes		 January 10, 1985







				- 2 -



     given to  existing	 technology,  components,  or  systems	-
     historical	 experience  has  shown	 HP  products  to perform
     reliably in this environment.

     Products intended to be sold into	Industrial   environments
     should  follow one	 or  more  of the  following  procedures:
     subject   the   product   to  component   and    subassembly
     tests    in    the	   recommended	  accelerated  industrial
     environment,  protect  susceptible	 metals	 (Ag,  Cu,  etc),
     ensure  at	 least	 30   uinches	of gold	on all	separable
     connectors,   and	 include   special   isolation	 measures
     (internal air purification, humidity control, etc).

     Severe environment	products generally cannot be achieved  by
     material  selection  alone	- the environment must be reduced
     to	 the  industrial  level	 by  customer  air   purification
     equipment,	 or  enclosure	of  the	 HP  equipment in NEMA or
     equivalent	enclosure.